FlexShield designs and delivers passive EMF shielding for Data Centers and high‑sensitivity environments, ensuring compliance, reliability, and long‑term performance.
Low‑frequency electromagnetic fields generated by transformers, high‑voltage lines, busbars, and high‑power cables are a growing technical and regulatory challenge. Increased power density and proximity to sensitive electronics drive failures, performance degradation, and exposure risks. FlexShield ensures reliability, compliance, and safety.
Electromigration, hot‑electron effects, antenna radiation, and long‑term exposure risks impacting people and equipment.
Up to 15% of electronic equipment failures are linked to EMF interference in critical environments.
Long‑term EMF exposure can impact health; compliance limits protect staff and occupants.
EMF interference increases failure rates and degrades sensitive electronics performance.
Shielding safeguards uptime in mission‑critical facilities.
We design solutions for transformer rooms, cable trays, busbars, and sensitive areas such as data halls, labs, and cleanrooms. Each design is tuned to exposure targets and operational constraints.
Validated in laboratory and on‑site conditions with documented results.
High‑permeability and high‑conductivity materials work together to deliver absorption and eddy‑current cancellation at low frequencies.
Shield transformer rooms, cable trays and busbars, or protect sensitive server rooms, labs, and cleanrooms near EMF sources.
Performance‑equivalent shielding with recycled metals to reduce CO2 and water footprint without compromising certification.
Standard, High‑Performance, and Ultra‑High‑Performance trays for power and data runs.
Standard, High‑Performance, and Ultra‑High‑Performance backplanes for sensitive zones.
Flat and corner plates with overlap “belt” system to minimize EMF leakage.
High‑attenuation channels for high‑current distribution lines.
Side, ceiling, or full protection configurations for transformer rooms.
Complete accessory system for installation, grounding, and continuity.
We combine assessment, design, validation, and on‑site verification to ensure measurable attenuation.
Audit
Source mapping, measurements, and exposure targets.
Design
Hybrid material selection and layout planning.
Test
Lab validation with repeatable data.
Verify
On‑site QA and performance reporting.
FlexShield designs to meet or exceed strict exposure limits for people and sensitive equipment.
Level 1: 1.25 microtesla for highly sensitive lab equipment.
Level 2: 3.75 microtesla for computer servers and data centers.
NCRP: 1 microtesla for human exposure.
Semiconductor fabs: 0.03 microtesla typical requirement.
MRI manufacturers: up to 1 microtesla in adjacent spaces.
Protection for patients, staff, and nearby equipment.
IEC/EN 61000‑4‑8 for equipment immunity and NCRP guidance for human exposure.
IEC/EN 61000‑4‑3 exposure thresholds for sensitive electronic systems.
As Low As Reasonably Achievable to minimize long‑term exposure risks.
All FlexShield solutions are validated in controlled laboratory conditions using real‑scale test setups.
EMF generator (HAEFFLY MAG 100), loop antenna, high‑precision EMF meters, and real‑scale test rooms.
Repeatable and documented attenuation data validated by independent laboratories and TÜV witness testing.
Design and testing for demanding cases, including ultra‑high‑performance cable trays for advanced photolithography tools.
After installation, EMF measurements are performed on site to verify real‑world performance under operational conditions.
Grid‑based measurements below shielded soffits, walls, and sensitive areas.
Verification of grounding, continuity, and final attenuation values against applicable standards.
Test conditions, witness tests, and measurement reports provide repeatable proof of performance.
Representative projects across Europe and the USA.
Transformer rooms, switchgear, and busbar containment.
Ultra‑high performance shielding for photolithography tools.
Protection of adjacent spaces and sensitive equipment.
Communications rooms and critical systems near high loads.
EMF expertise
Mission‑critical projects
Global deployments
FlexShield has delivered EMF solutions for data centers and semiconductor industry for over 30 years, with more than 300 mission‑critical installations worldwide.
FlexShield continues the legacy of the AST team, acquired by Schneider Electric in 2014, with pioneering EMF shielding technology since the EMC Directive in 1992.
Close collaboration with IBM, HP, Infineon, Intel and other industry leaders has built extensive know‑how in shielding sources and sensitive areas.
Entrepreneur and pioneer with 30+ years in the data center industry and a background in risk engineering and sustainability.
Mechanical and electrical engineer with data center engineering leadership for global hyperscale projects.
Former AST Modular co‑founder and senior executive with extensive operational and manufacturing experience.
Marketing and data center sector leadership with 10+ years of experience.
Computer engineering background with experience in environmental programs.
15 years of experience in shielding and data center projects.
Strategy, finance, and project planning expertise in European markets.
Business management leadership with big‑four consulting background.
Electrical engineer with leadership roles across ABB, Eaton, and Jacobs Engineering.
15 years leading AST and FlexShield sales with global power generation expertise.
FlexShield solutions have been successfully implemented across a wide range of industries and applications, including Data Centers, industrial facilities, public infrastructure, transportation hubs, research laboratories, and government buildings. Our customer base includes leading global corporations, public authorities, and critical infrastructure operators.
Independent certification of laboratory results.
Design aligned to low‑frequency EMF standards.
Documented measurements and on‑site validation.
Protection for people and sensitive equipment.
For complete specifications, models, dimensions, and guides, download the full catalog.
Open catalog (PDF)Share your floor plans and EMF measurements to receive a tailored shielding approach, cost estimate, and compliance roadmap.