Low‑Frequency EMF Shielding Solutions

Protect critical loads from low‑frequency electromagnetic fields.

FlexShield designs and delivers passive EMF shielding for Data Centers and high‑sensitivity environments, ensuring compliance, reliability, and long‑term performance.

30+ years of EMF expertise
350+ global installations
Up to 50x attenuation
FlexShield EMF shielding banner
01
Up to 50x attenuation Hybrid passive shielding across full installations.
02
Independent validation TÜV witness testing and documented measurements.
03
Lower footprint Recycled‑metal solutions reduce CO2 impact.

Why EMF shielding matters

Low‑frequency electromagnetic fields generated by transformers, high‑voltage lines, busbars, and high‑power cables are a growing technical and regulatory challenge. Increased power density and proximity to sensitive electronics drive failures, performance degradation, and exposure risks. FlexShield ensures reliability, compliance, and safety.

Key risks we eliminate

Electromigration, hot‑electron effects, antenna radiation, and long‑term exposure risks impacting people and equipment.

Up to 15% of electronic equipment failures are linked to EMF interference in critical environments.

HF
Human exposure

Long‑term EMF exposure can impact health; compliance limits protect staff and occupants.

EQ
Equipment integrity

EMF interference increases failure rates and degrades sensitive electronics performance.

OP
Operational continuity

Shielding safeguards uptime in mission‑critical facilities.

Solutions

Shield the source, or protect the sensitive zone

We design solutions for transformer rooms, cable trays, busbars, and sensitive areas such as data halls, labs, and cleanrooms. Each design is tuned to exposure targets and operational constraints.

50xAttenuation in critical zones
350+Installations worldwide
30+Years of field expertise
EMF shielding installation
Shielding solutions for critical environments
Critical environments

Engineered for performance, compliance, and safety

Validated in laboratory and on‑site conditions with documented results.

FlexShield technology

Hybrid shielding

Dual protection across installations

High‑permeability and high‑conductivity materials work together to deliver absorption and eddy‑current cancellation at low frequencies.

Up to 50x attenuation

Source and sensitive‑area strategies

Shield transformer rooms, cable trays and busbars, or protect sensitive server rooms, labs, and cleanrooms near EMF sources.

Sustainable design

Recycled‑metal solutions

Performance‑equivalent shielding with recycled metals to reduce CO2 and water footprint without compromising certification.

Product families

Cable trays

Shielded Trays (ST / HPT / UHPT)

Standard, High‑Performance, and Ultra‑High‑Performance trays for power and data runs.

Backplanes

Shielded Backplanes (SPP / HPP / UHPP)

Standard, High‑Performance, and Ultra‑High‑Performance backplanes for sensitive zones.

Plates

Shielding Plates

Flat and corner plates with overlap “belt” system to minimize EMF leakage.

Channels

Shielding Channels

High‑attenuation channels for high‑current distribution lines.

Transformers

Shielded Transformer Cages

Side, ceiling, or full protection configurations for transformer rooms.

Accessories

Supports and Fasteners

Complete accessory system for installation, grounding, and continuity.

Models and Dimensions

Installation examples

Representative wall support and installation examples from executed projects.

Key advantages

Standardized and scalable

  • Standard tray, high‑performance, and ultra‑high‑performance options.
  • Wide range of models, sizes, and shielding levels.
  • Easy selection through standardized configurations.

Installation efficiency

  • Overlapping Shield‑Tray segments reduce EMF leakage.
  • Shield‑Tray design supports efficient air cooling of power cables.
  • Quick installation with complete accessory system.
  • Suitable for horizontal and vertical cable risers.

Reliability and safety

  • Certified performance with documented attenuation.
  • Integrated earthing connection points.
  • Anti‑corrosion treatment and 10‑year warranty.

End‑to‑end shielding process

We combine assessment, design, validation, and on‑site verification to ensure measurable attenuation.

1

Audit
Source mapping, measurements, and exposure targets.

2

Design
Hybrid material selection and layout planning.

3

Test
Lab validation with repeatable data.

4

Verify
On‑site QA and performance reporting.

Limits and standards

FlexShield designs to meet or exceed strict exposure limits for people and sensitive equipment.

IEC/EN 61000‑4‑8

Level 1: 1.25 microtesla for highly sensitive lab equipment.

Level 2: 3.75 microtesla for computer servers and data centers.

Other references

NCRP: 1 microtesla for human exposure.

Semiconductor fabs: 0.03 microtesla typical requirement.

Healthcare environments

MRI manufacturers: up to 1 microtesla in adjacent spaces.

Protection for patients, staff, and nearby equipment.

Compliance and recommendations

Low‑frequency limits

IEC/EN 61000‑4‑8 for equipment immunity and NCRP guidance for human exposure.

High‑frequency guidance

IEC/EN 61000‑4‑3 exposure thresholds for sensitive electronic systems.

ALARA principle

As Low As Reasonably Achievable to minimize long‑term exposure risks.

Laboratory validation

All FlexShield solutions are validated in controlled laboratory conditions using real‑scale test setups.

FlexShield Labs

EMF generator (HAEFFLY MAG 100), loop antenna, high‑precision EMF meters, and real‑scale test rooms.

Certified results

Repeatable and documented attenuation data validated by independent laboratories and TÜV witness testing.

Custom solutions

Design and testing for demanding cases, including ultra‑high‑performance cable trays for advanced photolithography tools.

On‑site testing and QA

After installation, EMF measurements are performed on site to verify real‑world performance under operational conditions.

Field measurements

Grid‑based measurements below shielded soffits, walls, and sensitive areas.

Completion checks

Verification of grounding, continuity, and final attenuation values against applicable standards.

Documented validation

Test conditions, witness tests, and measurement reports provide repeatable proof of performance.

Executed data center projects

Representative projects across Europe and the USA.

Data Center shielding

Transformer rooms, switchgear, and busbar containment.

Semiconductor fabs

Ultra‑high performance shielding for photolithography tools.

Hospitals and MRI

Protection of adjacent spaces and sensitive equipment.

Airports & infrastructure

Communications rooms and critical systems near high loads.

Project snapshots

A glimpse of our shielding installations and test environments.

Applications

Data centers and network rooms
Semiconductor fabs
Pharmaceutical and biotech labs
Hospitals, MRI and X‑ray areas
Industrial facilities and factories
Airports and transport infrastructure
High‑voltage line exposure mitigation
Telecom rooms and backup sites

Proven experience

30+ years

EMF expertise

350+

Mission‑critical projects

EU and USA

Global deployments

Company background

What we do

FlexShield has delivered EMF solutions for data centers and semiconductor industry for over 30 years, with more than 300 mission‑critical installations worldwide.

Origins

FlexShield continues the legacy of the AST team, acquired by Schneider Electric in 2014, with pioneering EMF shielding technology since the EMC Directive in 1992.

Partnerships

Close collaboration with IBM, HP, Infineon, Intel and other industry leaders has built extensive know‑how in shielding sources and sensitive areas.

Timeline highlights

1993 First shielding projects aligned to EMC Directive.
1999 AST founded, focused on shielding projects.
2004 EMF Lab created and standardized, certified shielding products launched.
2014 AST acquired by Schneider Electric.
2018 FlexShield brand launched.
2023 New recycled‑metal shielding solutions reduce CO2 footprint.

Core team

Henry Daunert

CEO

Entrepreneur and pioneer with 30+ years in the data center industry and a background in risk engineering and sustainability.

Miguel Pascual

CTO

Mechanical and electrical engineer with data center engineering leadership for global hyperscale projects.

Max Daunert

COO

Former AST Modular co‑founder and senior executive with extensive operational and manufacturing experience.

Patricia Saenger

Project Manager

Marketing and data center sector leadership with 10+ years of experience.

Rayhan Ali Khan

Technical Director

Computer engineering background with experience in environmental programs.

Luis Mulero

Senior Project Director

15 years of experience in shielding and data center projects.

Lukas Hinderthur

DACH Business Development

Strategy, finance, and project planning expertise in European markets.

Felix Hinderthur

DACH Managing Director

Business management leadership with big‑four consulting background.

Patrick Giangrosso

Chief Innovation Officer

Electrical engineer with leadership roles across ABB, Eaton, and Jacobs Engineering.

Maxim Escriche

Sales Director

15 years leading AST and FlexShield sales with global power generation expertise.

Customer references

FlexShield solutions have been successfully implemented across a wide range of industries and applications, including Data Centers, industrial facilities, public infrastructure, transportation hubs, research laboratories, and government buildings. Our customer base includes leading global corporations, public authorities, and critical infrastructure operators.

Certifications

TÜV witness testing

Independent certification of laboratory results.

IEC/EN 61000‑4‑8

Design aligned to low‑frequency EMF standards.

Repeatable QA

Documented measurements and on‑site validation.

Exposure compliance

Protection for people and sensitive equipment.

Catalog

For complete specifications, models, dimensions, and guides, download the full catalog.

Open catalog (PDF)

Plan your EMF mitigation strategy

Share your floor plans and EMF measurements to receive a tailored shielding approach, cost estimate, and compliance roadmap.